+6 016 7988 269 +65 8292 3799. Foldable furniture. The award winning Dutch foldable designer chair’ looks like a giant envelope and it turns into a. Jun 01, 2015 Heat flux sensors and thermocouples (type T) are placed on each side of the composite are specifically chosen for the purposes of the dynamic experiment presented in this paper. The heat flux film used in the experiment is a square heat flux sensor produced by Captec and has the sensitivity of 202 μV/W/m 2.
Abstract
Infrared ear thermometers (IRETs) are extensively used for measuring the temperature of a human body. For accurate measurements with IRETs they have to be calibrated regularly with an appropriate and traceable calibration system. Such systems are neither widely available nor are there many competent (accredited) laboratories which can provide traceability for IRETs. This paper describes some important influential parameters in the calibration and use of IRETs, which were observed during the extensive research on IRETs and have not been reported in the literature yet. IRET readings, and consequently also their most important metrological characteristics, accuracy and uncertainty of measurement, depend on these influential parameters. According to our findings, we would like to warn users of medical radiation thermometers, not only IRETs but also forehead thermometers and infrared temperature scanning systems, that they should be extremely careful in selection, maintenance and use of medical radiation thermometers. Measurement accuracy, as it is required by several technical standards, is hard to achieve with the majority of currently available medical radiation thermometers.
Export citation and abstract
Access this article
Login options
Individual loginorInstitutional login
via Athens/ShibbolethorIPEM member access
The computer you are using is not registered by an institution with a subscription to this article. Please log in below. Find out more about journal subscriptions at your site.
Rent or Purchase this article online
Make a recommendation
To gain access to this content, please complete the Recommendation Form and we will follow up with your librarian or Institution on your behalf.
For corporate researchers we can also follow up directly with your R&D manager, or the information management contact at your company.
Institutional subscribers have access to the current volume, plus a 10-year back file (where available).
0022-3735/17/6/016Abstract
An electromagnetic flowmeter is described which uses electrodes of large area coated with insulating film made of the plastic polymer FEP. The surface impedance of the electrode-liquid interface is both highly uniform and stable: it is free from polarisation impedance and is much less affected by solid deposits than the interfacial impedance of conventional contact electrodes. Consequently, electrodes of large area can be used with good baseline stability. It is also possible to achieve a low noise level. A flowmeter with such electrodes and a quasi-uniform magnetic field represents an approach to the realisation of a stable, efficient electromagnetic flowmeter which is insensitive to the velocity distribution of the flowing liquid. Such instruments could be used for the accurate measurement of flow near bifurcations for the accurate measurement of the flow of liquids having a wide range of conductivity (e.g. >10-5 S m-1) and for measuring the flow of corrosive liquids.
Export citation and abstract
Access this article
Login options
Individual loginorInstitutional login
via Athens/Shibboleth
The computer you are using is not registered by an institution with a subscription to this article. Please log in below. Find out more about journal subscriptions at your site.
Rent or Purchase this article online
Make a recommendation
To gain access to this content, please complete the Recommendation Form and we will follow up with your librarian or Institution on your behalf.
For corporate researchers we can also follow up directly with your R&D manager, or the information management contact at your company.
Flux 6.016 Download
Flux 6.016 2
Institutional subscribers have access to the current volume, plus a 10-year back file (where available).